PROLiNK Master II Series (3P/3P) - Tower PRO833200FL

Rp 1.472.089.500

Item Code : #SPR0350097

Availability : In stock

Condition : New

PROLiNK Master II Series (3P/3P) Tower is a there-phase output UPS system that employs a true online double-conversion technology. Double conversion between input/output, battery adn bypass are totally isolated power line noise, spike and transients, keeping power failure away from critical loads. It is designed to deliver clean and high quality electrical power for electrical loads. High input power factor correction in the system improves the efficiency and reduces overall losses. DSP control technology is implemented for the UPS system to improve performance and real time harmonic cancellation. UPS is also equipped with 3-stage smart charging design to optimize battery performance. Tjis feature extends the useful service life of battery and optimizes battery recharge time.

SKUSPR0350097
TypePRO833200FL
MPNPRO833200FL
Weight335 Kg
BrandPROLiNK
KategoriPower Back Up
Dimensi1040 x 567 x 1442 mm
Phase 3-phase in / 3-phase out
Capacity 200KVA/180KW
Nominal Voltage IN 3 x400 VAC (3Ph+N)
Voltage Range IN 208-478 VAC (3-phase) @ 70 percent load, 305-478 VAC (3-phase) @ 100 percent load
Frequency Range IN 40~70Hz
Power Factor IN >= 0.99 @ 100 percent Load
Output Voltage 3 x 360 /380/400/415 VAC (3Ph+N)
AC Voltage Regulation (Batt. Mode) +/- 1 percent
Frequency Range (Synchronized Range) 46~54Hz or 56~64Hz
Current Crest Ratio 3:1(max.)
Harmonic Distortion <=2 percent THD (Linear Load), <= 4 percent THD (Non-linear Load)
AC Mode to Batt. Mode Transfer Time Zero
Inverter to Bypass Transver Time Zero
Waveform (Batt. Mode) Pure Sine Wave
AC Mode Overload 105-110 percent for 1 hr, 111-125 percent for 10 min, 126-150 percent for 1 min , > 150 percent for 200 ms
Battery Mode Overload 105-110 percent for 1hr, 111-125 percent for 10 min,126 - 150 percent for 1min, >150 percent for 200 ms
Parallel Capacity Up to 2 units in parallel
AC Mode Efficiency 94.5 percent
ECO Mode Efficiency 98.0 percent
Battery Mode Efficiency 94.5 percent
Battery Type (Standadr Model) N/A
Battery Numbers (Standadr Model) N/A
Typical Rechargre Time (Standadr Model) N/A
Charging Current (max.)(Standadr Model) N/A
Charging Voltage(Standadr Model) N/A
Long-run Model Battery Type Depending on the capacity of external batteries
Long-run Model Battery Numbers 32~40 pcs (adjustable)
Long-run Model Charging Current (Max.) 48A
Long-run Model Charging Voltage +/- 13.65V x N (N=16~20)
LCD Display UPS status, Load level, Input/Output voltage, Discharge timer, and Fault conditions
Alarm Battery Mode Sounding every 4 seconds
Alarm Low Battery Sounding every seconds
Alarm Overload Sounding twice every second
Alarm Fault Continously Sounding
Standard Model Dimension N/A
Standard Net Weight N/A
Long-run Model Dimension 1040 x 567 x 1442
Long-run Net Weight 335 kg
Operation Temperture 0-40 C
Operation Humidity <95 percent and non-condersing
Noise Level Less tahn 73dB @ 1 Meter
Smart RS-232 / USB Support Windows 2000/2003/XP/Vista/2008, Windows 7/8/10
Optional SNMP Power Management from SNMP manager and web browser
Join our newsletter