Smart Computerindo - smartcomputerindo.com
...

PROLiNK Master II Series (3P/3P) - Tower PRO83340FL

Rp 176.895.834

Item Code : #SPR0350091

Availability : In stock

Condition : New

PROLiNK Master II Series (3P/3P) Tower is a there-phase output UPS system that employs a true online double-conversion technology. Double conversion between input/output, battery adn bypass are totally isolated power line noise, spike and transients, keeping power failure away from critical loads. It is designed to deliver clean and high quality electrical power for electrical loads. High input power factor correction in the system improves the efficiency and reduces overall losses. DSP control technology is implemented for the UPS system to improve performance and real time harmonic cancellation. UPS is also equipped with 3-stage smart charging design to optimize battery performance. Tjis feature extends the useful service life of battery and optimizes battery recharge time.

SKUSPR0350091
TypePRO83340FL
MPNPRO83340FL
Weight230 Kg
BrandPROLiNK
KategoriPower Back Up
Dimensi815 x 300 x 1000 mm
Phase 3-phase in / 3-phase out
Capacity 40KVA/36KW
Nominal Voltage IN 3 x400 VAC (3Ph+N)
Voltage Range IN 190-520 VAC (3-phase) @ 50 percent load, 305-478 VAC (3-phase) @ 100 percent load
Frequency Range IN 46~54Hz or 56~64Hz
Power Factor IN >= 0.99 @ 100 percent Load
Output Voltage 3 x 360 /380/400/415 VAC (3Ph+N)
AC Voltage Regulation (Batt. Mode) +/- 1 percent
Frequency Range (Synchronized Range) 46~54Hz or 56~64Hz
Current Crest Ratio 3:1(max.)
Harmonic Distortion <=2 percent THD (Linear Load), <= 4 percent THD (Non-linear Load)
AC Mode to Batt. Mode Transfer Time Zero
Inverter to Bypass Transver Time Zero
Waveform (Batt. Mode) Pure Sine Wave
AC Mode Overload 100-110 percent for 10 min, 110-130 percent for 1 min, > 130 percent for 1 second
Battery Mode Overload 100-110 percent for 30 seconds, 110-13- percent for 10 Seconds, >130 percent for 1 second
Parallel Capacity Up to 3 units in parallel
AC Mode Efficiency 94.5 percent
ECO Mode Efficiency 98.0 percent
Battery Mode Efficiency 94.5 percent
Battery Type (Standadr Model) 12V/9Ah
Battery Numbers (Standadr Model) (16+16)pcs x 2 strings
Typical Rechargre Time (Standadr Model) 9 Hours recover to 90 percent capacity
Charging Current (max.)(Standadr Model) 2A
Charging Voltage(Standadr Model) +/- 218 VDC
Long-run Model Battery Type Depending on the capacity of external batteries
Long-run Model Battery Numbers 32~40 pcs (adjustable)
Long-run Model Charging Current (Max.) 4A
Long-run Model Charging Voltage +/- 13.65V x N (N=16~20)
LCD Display UPS status, Load level, Input/Output voltage, Discharge timer, and Fault conditions
Alarm Battery Mode Sounding every 4 seconds
Alarm Low Battery Sounding every seconds
Alarm Overload Sounding twice every second
Alarm Fault Continously Sounding
Standard Model Dimension 815 x 300 x 1000
Standard Net Weight 230 kg
Long-run Model Dimension 815 x 300 x 1000
Long-run Net Weight 61 kg
Operation Temperture 0-40 C
Operation Humidity <95 percent and non-condersing
Noise Level Less tahn 70dB @ 1 Meter
Smart RS-232 / USB Support Windows 2000/2003/XP/Vista/2008, Windows 7/8/10
Optional SNMP Power Management from SNMP manager and web browser