PROLiNK Master II Series (3P/3P) Tower is a there-phase output UPS system that employs a true online double-conversion technology. Double conversion between input/output, battery adn bypass are totally isolated power line noise, spike and transients, keeping power failure away from critical loads. It is designed to deliver clean and high quality electrical power for electrical loads. High input power factor correction in the system improves the efficiency and reduces overall losses. DSP control technology is implemented for the UPS system to improve performance and real time harmonic cancellation. UPS is also equipped with 3-stage smart charging design to optimize battery performance. Tjis feature extends the useful service life of battery and optimizes battery recharge time.
SKU | SPR0350091 |
Type | PRO83340FL |
MPN | PRO83340FL |
Weight | 230 Kg |
Brand | PROLiNK |
Kategori | Power Back Up |
Dimensi | 815 x 300 x 1000 mm |
Phase | 3-phase in / 3-phase out |
Capacity | 40KVA/36KW |
Nominal Voltage IN | 3 x400 VAC (3Ph+N) |
Voltage Range IN | 190-520 VAC (3-phase) @ 50 percent load, 305-478 VAC (3-phase) @ 100 percent load |
Frequency Range IN | 46~54Hz or 56~64Hz |
Power Factor IN | >= 0.99 @ 100 percent Load |
Output Voltage | 3 x 360 /380/400/415 VAC (3Ph+N) |
AC Voltage Regulation (Batt. Mode) | +/- 1 percent |
Frequency Range (Synchronized Range) | 46~54Hz or 56~64Hz |
Current Crest Ratio | 3:1(max.) |
Harmonic Distortion | <=2 percent THD (Linear Load), <= 4 percent THD (Non-linear Load) |
AC Mode to Batt. Mode Transfer Time | Zero |
Inverter to Bypass Transver Time | Zero |
Waveform (Batt. Mode) | Pure Sine Wave |
AC Mode Overload | 100-110 percent for 10 min, 110-130 percent for 1 min, > 130 percent for 1 second |
Battery Mode Overload | 100-110 percent for 30 seconds, 110-13- percent for 10 Seconds, >130 percent for 1 second |
Parallel Capacity | Up to 3 units in parallel |
AC Mode Efficiency | 94.5 percent |
ECO Mode Efficiency | 98.0 percent |
Battery Mode Efficiency | 94.5 percent |
Battery Type (Standadr Model) | 12V/9Ah |
Battery Numbers (Standadr Model) | (16+16)pcs x 2 strings |
Typical Rechargre Time (Standadr Model) | 9 Hours recover to 90 percent capacity |
Charging Current (max.)(Standadr Model) | 2A |
Charging Voltage(Standadr Model) | +/- 218 VDC |
Long-run Model Battery Type | Depending on the capacity of external batteries |
Long-run Model Battery Numbers | 32~40 pcs (adjustable) |
Long-run Model Charging Current (Max.) | 4A |
Long-run Model Charging Voltage | +/- 13.65V x N (N=16~20) |
LCD Display | UPS status, Load level, Input/Output voltage, Discharge timer, and Fault conditions |
Alarm Battery Mode | Sounding every 4 seconds |
Alarm Low Battery | Sounding every seconds |
Alarm Overload | Sounding twice every second |
Alarm Fault | Continously Sounding |
Standard Model Dimension | 815 x 300 x 1000 |
Standard Net Weight | 230 kg |
Long-run Model Dimension | 815 x 300 x 1000 |
Long-run Net Weight | 61 kg |
Operation Temperture | 0-40 C |
Operation Humidity | <95 percent and non-condersing |
Noise Level | Less tahn 70dB @ 1 Meter |
Smart RS-232 / USB | Support Windows 2000/2003/XP/Vista/2008, Windows 7/8/10 |
Optional SNMP | Power Management from SNMP manager and web browser |