Smart Computerindo - smartcomputerindo.com
...

PROLiNK Professional Series 1P/1P Online UPS 1000VA PRO901WS

Rp 5.895.000

Item Code : #SPR0350008

Availability : In stock

Condition : New

The Professional Series (1P/1P) - Tower is an advanced, affordable on-line double-conversion technology single-phase UPS system. Tower versions are available with 1000VA to 10000VA models and these offer high reliability for workstations, server and network equipment. The Professional Series is designed with automatic voltage regulation (AVR) to protect against power outages, disturbances and spikes. High voltage battery chargers and battery extension assembly is available for the long run time application.

SKUSPR0350008
TypePRO901WS
MPNPRO901WS
Weight10.5 Kg
BrandPROLiNK
KategoriPower Back Up
Dimensi282 x 145 x 220 mm
Type UPS Online UPS
Kapasitas 1000VA
Power Factor 0.99 @Nominal Voltage (100 Percent load)
Input Voltage Range 55-150VAC or 110-300VAC (Based on load at 50 Percent 85-140VAC or 160-280VAC (Based on load at 100 Percent )
Transfer Time AC Mode to Battery Mode : Zero, Inverter to Bypass : 4ms (Typical)
Feature True on-line double-conversion technology Single phase input and single phase output system High DC charging current for long back-up application Galvanic isolation design available to provide adequate isolation
Volt-Amp 1000 VA
Watt 800 W
Nominal Voltage 100/110/115/120/127VAC or 200/208/220/230/240VAC
Input Voltage Range 55-150VAC or 110-300VAC (Based on load at 50 Percent ,85-140VAC or 160-280VAC (Based on load at 100 Percent )
Frequency Range 40Hz ~ 70Hz
Power Factor ≥ 0.99 @Nominal Voltage (100 Percent load)
Output AC Voltage 100/110/115/120/127VAC or 200/208/220/230/240VAC
Voltage Regulation +/-1 Percent
Frequency Range (Synchronized Range) 47 ~ 53Hz or 57 ~ 63Hz
Frequency Range (Battery Mode) 50Hz +/-0.25Hz or 60Hz +/- 0.3Hz
Current Crest Ratio 3 : 1
Linear Load ≤3 Percent THD
Non-Linear Load ≤6 Percent THD
AC Mode to Battery Mode Zero
Inverter to Bypass 4ms (Typical)
Battery Type 12V9AH
Typical Recharge Time 4 hours recover to 90 Percent capacity
Battery Type Depending on the capacity of external batteries
Charging Current (max.) 1A/2A/4A/6A (Adjustable)
LCD Panel Load Level, Battery Level, AC mode, Bypass mode, and Fault Conditions
Battery Model Sounding every 4 seconds
Low Battery Sounding every seconds
Overload Sounding twice every seconds
Fault Continuously sounding
Dimension (mm) D×W×H 282 x 145 x 220
Net Weight (kgs) 9.8
Humidity 20~90 Percent RH @ 0~40°C (Non-Condensing)
Noise Level Less than 50dB @ 1 Meter
Smart RS232 / USB Support Windows® 2000/2003/XP/Vista/2008, Windows® 7/8, Linux, Unix and MAC
Optional SNMP Power management from SNMP manager and web browser
Join our newsletter